MURALO CO INC -- QUIK-TRED ACRYLIC LATEX FLOOR & PATIO PAINT -- 8010-00N012012
=====================  Product Identification  =====================

Product ID:QUIK-TRED ACRYLIC LATEX FLOOR & PATIO PAINT
MSDS Date:01/10/1986
FSC:8010
NIIN:00N012012
=== Responsible Party ===
Company Name:MURALO CO INC
Address:148 EAST 5TH ST
City:BAYONNE
State:NJ
ZIP:07002
Country:US
Info Phone Num:201-437-0770
Emergency Phone Num:201-437-0770
CAGE:MURAL
=== Contractor Identification ===
Company Name:MURALO CO INC
Address:148 EAST 5TH ST
City:BAYTONE
State:NJ
ZIP:07002
Country:US
Phone:201-437-0770
CAGE:MURAL
Company Name:THE MUROLO CO INC
Address:148 E 5TH ST
Box:City:BAYONNE
State:NJ
ZIP:07002
Country:US
Phone:201-437-0770
CAGE:91953

=============  Composition/Information on Ingredients  =============

Ingred Name:PHENYLMERCURIC ACETATE  (SARA III)
CAS:62-38-4
RTECS #:OV6475000
Fraction by Wt: .01%
OSHA PEL:0.1 MG HG/M3;CEIL;S
ACGIH TLV:0.01 MG HG/M3; 9192
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:AMMONIUM HYDROXIDE	(SARA III)
CAS:1336-21-6
RTECS #:BQ9625000
Fraction by Wt: .60%
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:HYPERSENSITIVE INDIVIDUALS MAY
    EXPERIENCE SOME SKIN SENSITIZATION OR IRRITATION. CHRONIC: NONE
    KNOWN
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE KNOWN

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH IMMEDIATELY WITH LARGE AMOUNTS OF WATER FOR 15
    MIN.GET MD. SKIN:WASH AFFECTED AREAS WITH SOAP AND WATER. GET MD IF
    IRRITATION PERSISTS.INGEST: DRINK 1-2 GLASSES OF WATER TO DILUTE.
    DO NOT  INDUCE VOMITING.GET MD IMMED. INHAL: REMOVE TO FRESH AIR .

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE DUE TO
    BUILD UP OF STEAM PRESSURE WHEN EXPOSED TO EXTREME HEAT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE ABSORBENT MATERIAL SUCH AS SAND TO PICK UP
    EXCESS, WASH AREA  WITH SOAP AND WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE CONTAINERS BETWEEN 40 AND
    100F.PROTECT FROM FREEZING.
Other Precautions:NONE

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED.
Ventilation:OPEN WINDOWS. CONSULT LOCAL/SAFETY HEALTH AUTHORITIES IF
    ADDITIONAL GUIDANCE IS NEEDED.
Protective Gloves:NONE REQUIRED
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:FULL LENGTH CLOTHING TO AVOID PROLONGED &
    REPEATED CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:212F(WATER)
Vapor Pres:SEE INGRED
Vapor Density:>AIR
Spec Gravity:1.25
Evaporation Rate & Reference: