PRAXAIR INC -- ARGON -- 6685-00-292-1189
===================== Product Identification =====================
Product ID:ARGON
MSDS Date:12/01/1992
FSC:6685
NIIN:00-292-1189
=== Responsible Party ===
Company Name:PRAXAIR INC
Address:39 OLD RIDGEBURY RD
City:DANBURY
State:CT
ZIP:06817-0001
Country:US
Info Phone Num:203-794-5782
Emergency Phone Num:203-794-5782/800-424-9300(CHEMTREC)
CAGE:0LV01
=== Contractor Identification ===
Company Name:MOELLER INSTRUMENT CO
Address:126 MAIN ST
Box:668
City:IVORYTON
State:CT
ZIP:06442
Country:US
Phone:860-767-2104
CAGE:76526
Company Name:PRAXAIR, INC.
Address:39 OLD RIDGEBURY RD
Box:City:DANBURY
State:CT
ZIP:06810-5113
Country:US
Phone:800-772-9247; 800-PRAXAIR
CAGE:0LV01
============= Composition/Information on Ingredients =============
Ingred Name:ARGON
CAS:7440-37-1
RTECS #:CF2300000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
ACGIH TLV:ASPHYXIANT; 9596
===================== Hazards Identification =====================
LD50 LC50 Mixture:TLV:SIMPLE ASPHYXIANT, 0.5MG/M3
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:PROD GAS @NORMAL
TEMP/PRESSURE.SKIN ABSORP:NO EVIDENCE OF ADVERSE EFFECTS FRM AVAI
INFO.INHAL:ASPHYXIANT.MODERATE CONC MAY CAUSE
HEAD,DROWS,DIZZ,EXCITATION,EXCESS SALIVATION,VOMIT,UNCONSC.SKIN/
EYE:NO HARMFUL EFFECT EXPECTED FRM VAP.CHRONIC:NO EVIDENCE OF
ADVERSE EFFECTS FRM AVAI INFO.WORKING W/WELD/CUT MAY (SUP)
Effects of Overexposure:ARGON AN ASPHYXIANT.LACK OF OXYGEN CAN CAUSE
DEATH. SHORT TERM OVEREXPO TO WELD/CUT FUMES MAY RESULT IN
DISCOMFORT SUCH AS DIZZ,NAU,DRYNESS OR IRRIT OF NOSE/THROAT/EYES.
Medical Cond Aggravated by Exposure:A KNOWLEDGE OF AVAI TOXICLOLOGY
INFO & OF PHYS/CHEM PROPERTIES OF MATL SUGGEST THAT OVEREXPO IS
UNLIKELY TO AGGRAVATE EXISTING MED CONDITIONS.
======================= First Aid Measures =======================
First Aid:INGEST:PRODU GAS @NORMAL TEMP/PRESSURE.SKIN:FLUSH
W/ATER.INHAL:REMOVE TO FRESH AIR.GIVE ARTIFICIAL RESP IF NOT
BREATHING.GIVE OXYGEN IF BREATHING IS DIFFICULT.CALL
PHYSICIAN.EYE:FLUSH W/WATER.NOTE TO DR:PRODUCT IS INERT.THERES NO
SPECIFIC ANTIDOTE.TREATMENT OF OVEREXPO SHOULD BE DIRECTED @CONTROL
OF SYMPTOMS & CLINICAL CONDITIONS.
===================== Fire Fighting Measures =====================
Autoignition Temp:Autoignition Temp Text:NA
Lower Limits:N/APPLICABLE
Upper Limits:N/APPLICABLE
Extinguishing Media:ARGON CANNOT CATCH FIRE.USE MEDIA APPROPRIATE FOR
SURROUNDING FIRE.
Fire Fighting Procedures:EVACUATE ALL PERSON FRM DANGER AREA.IMMED COOL
CNTNR W/WATERSPRAY FRM MAX DISTANCE TIL COOL,THEN MOVE CNTNR AWAY
FROM FIRE AREA W/O RISK.SHUT OFF LEAD W/O RISK.
Unusual Fire/Explosion Hazard:ARCS/SPARK IGN COMBUST.REF:ANSZ49.1.CNTNR
MAY RUPTURE DUE TO FIRE HEAT.NO PART OF CNTNR SHOULD BE SUBJ TO
TEMP >52C.MOST CNNTR PROVIDED W/PRESUSE RELIEF(SUPPLE)
================== Accidental Release Measures ==================
Spill Release Procedures:ARGON ASPHYXIANT.EVACUATE ALL PERSON.USE SCBA
WHERE NEEDED.SHUT OFF CYL W/O RISK.VENTI AREA OR MOVE CYL TO WELL
VENTI AREA.TEST AREA ESPEC CONF AREA FOR SUFFI OXY CONTENT PRIOT TO
RE-ENTRY OF PERSONNE L.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:ARC/SPARK DURING USE COULD IGN SOURCE
FOR COMBUST MATL.PREVENT FIRES.SEE NFPA 51B.USE PIPING/EQPMT
ADEQUATE DESIGNED TO W/STAND PRESSURES ENCOUNTERED.
Other Precautions:GAS CAN CAUSE RAPID SUFFOCATION-OXY DEFFIC.STORE/USE
W/ADEQUATE VENTI.DONT ALLOW CYL TO BECOME PART OF ELECTR
CIRCUIT.READ/UNDERSTAND MFG INSGTRUCTIONS/PRECAUT LABEL.FUME/GAS
CANT BE CLASSIFIED SIMPLY -DEPENDS ON METAL,CONDITIONS,WORKER,ETC.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE AIR-PURIF/AIR-SUPP RESP AS APPROPR WHERE LOC
&/OR GEN EXHAU VENTI NOT ADEQUATE TO KEEP WORKER EXPO BEL
APPLICABLE TLV DURING WELD OPERATIONS W/ARGON.AIR SUPP RESP REQUIRE
WHILE WORK IN CONF SPACES .CONFORM RESP PROT USE W/29CFR1910.134.
Ventilation:LOC EXHAU-USE IF NECESASRY TO MAINTAIN HAZ FUMES/GAS CONCE
BEL APPLICABLE TLV IN WORK BREATH ZONE.MECH(GEN)-UNDER (SUPP)
Protective Gloves:WELDING GLOVES RECOMMENDED
Eye Protection:HELMET,FACESHIELD W/FILT PER ANSI Z49.1
Other Protective Equipment:PROVIDE PROT SCREEN/FLASH GOGG IF NECESSARY
TO PROT OTHER.SELECT PER 29CFR1910.133.HAND/HEAD/BODY PROT AS
NEED.DK CLOTH.
Work Hygienic Practices:SEE OSHA PUBLICATION 2206(29CFR1910) & PRAXAIR
PUBLICATION L-52-529.NEVER WORK ON PRESSURIZED SYSTEM.
Supplemental Safety and Health
FIRE/EXPLO:DEVICE DESIGNED TO VENT CONTENTS WHEN EXPO TO ELEV TEMP.
HEALTH:CREATE ADDN HEALTH HAZ.FUMES/GASES CAN BE DANGEROUS,MAY
CAUSE SERIOUS LUNG DISEASES. CONDITIONS AVOID:DONT STRIKE ARC ON
CYL. DONT GROUND CYL. VENTI:CERTAIN WORK CONDITIONS GENE EXHAU
VENTI MAY BE ACCEPTABLE PROVIDE THAT ADEQEQ TO MAINT BEL TLV.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:-301F,-185C
Melt/Freeze Pt:M.P/F.P Text:-309F,-189C
Decomp Temp:Decomp Text:NP
Vapor Pres:GAS
Vapor Density:1.378 @21C
Spec Gravity:GAS
pH:NP
Viscosity:NP
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS,ODORLESS GAS AT NORMAL TEMP & PRESSURE
Percent Volatiles by Volume:100
Corrosion Rate:NP
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE CURRENTLY KNOWN. ARGON IS CHEMICALLY INERT.
Stability Condition to Avoid:HI PRESSURE GAS.CLOSE VALVE WHEN NOT IN
USE/EMPTY.USE W/EQPMT RATED TO ADEQUATELY W/STAND PRESSREU TO BE
ENCOUNTERE(SUP)
Hazardous Decomposition Products:OZONE/NITROGEN OXIDES-FORM BY
RADIATION FRM ARC.OTHER OF NORM OPERATION FRM
VOLATILIZATION,REACTION OR OXIDATION OF MATL
==================== Disposal Considerations ====================
Waste Disposal Methods:SLOWLY RELEASE INTO ATM.DISCARD ANY
PRODUCT,RESIDUE,DISPOSABLE CNTNR OR LINER IN ENVIRONMENTALLY
ACCEPTABLE MANNER IN FULL COMPLIANCE W/FED/STATE/LOC REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.