TEXACO LUBRICANTS CO -- HAVOLINE OUTBOARD 2-CYCLE ENGINE OIL, 01596 -- 9150-00N021971
===================== Product Identification ===================== Product ID:HAVOLINE OUTBOARD 2-CYCLE ENGINE OIL, 01596 MSDS Date:12/05/1990 FSC:9150 NIIN:00N021971 === Responsible Party === Company Name:TEXACO LUBRICANTS CO Box:52332 City:HOUSTON State:TX ZIP:77052 Country:US Info Phone Num:914-838-7204 Emergency Phone Num:914-831-3400;800-424-9300(CHEMTREC) CAGE:OTTJ3 === Contractor Identification === Company Name:TEXACO INC CORPORATE HQ Address:2000 WESTCHESTER AVE City:WHITE PLAINS State:NY ZIP:10604 Country:US Phone:914-253-4000 CAGE:59595 Company Name:TEXACO LUBRICANTS Address:4164 E INNSLAKE DR Box:4427 City:GLEN ALLEN State:VA ZIP:23060 Country:US Phone:804-527-4311 CAGE:OTTJ3 ============= Composition/Information on Ingredients ============= Ingred Name:DISPERSANTS; (ADV PKG CONTAINING A POLYAMINE DISPERSANT) Fraction by Wt: 4-10.99% Ingred Name:MIN OIL,PETRO DISTILLATES,HYDROTREATD LGT NAPHTHENIC;(SEVERE SOLV-REFIND HYDROTREATD LIGHT NAPHTHENIC PETRO DISTILLATES) CAS:64742-53-6 RTECS #:PY8036000 Fraction by Wt: 65-80% OSHA PEL:5MG/M3(OILMIST)(MFR) ACGIH TLV:5MG/M3(OILMIST)(MFR) Ingred Name:HYDROTREATED C25 BRIGHT STOCK BASED LUBRICATING OIL CAS:72623-83-7 Fraction by Wt: 11-20% OSHA PEL:5 MG/M3 (MIST)(MFR) ACGIH TLV:5 MG/M3 (MIST)(MFR) Ingred Name:RESP PROT: ENTRY IN TANKS, VESSELS, OR OTHER CONFINED SPACES. RTECS #:9999999ZZ Ingred Name:SUPP DATA: HAZ. DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS . RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:(ACUTE)EYES:MAY CAUSE MINIMAL IRRIT, EXPERIENCED AS TEMP DISCOMFORT. SKIN:NO ADVERSE EFTS EXPECTED FROM ABSORP OF MATL THRU SKIN. BRIEF CONT MAY CAUSE SLIGHT IRRIT. PRLNGD CONT, AS W/ CLTHG WETTED W/M ATL, MAY CAUSE MORE SEVERE IRRIT & DISCOMFORT, SEEN AS LOCAL REDNESS & SWELLING. INHAL:VAPS/MIST, IN(SEE EFTS OF OVEREXP Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:EXCESS OF PERMISSIBLE CONC, OR IN UNUSUALLY HIGH CONC GENERATED FROM SPRAYING, HEATING MATL OR AS FROM EXPOS IN POORLY VENT AREAS/CONFINED SPACES, MAY CAUSE IRRIT OF NOSE & THROAT, HDCH, NAUS & DROWS. INGEST:NO ADVERSE EFTS EXPECTED. IF MORE THAN SEVERAL MOUTHFULS ARE SWALLOWED, ABDOM DISCOMFORT, (SUPP DATA) Medical Cond Aggravated by Exposure:BECAUSE OF ITS DEFATTING PROPERTIES, PROLONGED AND REPEATED SKIN CONTACT MAY AGGRAVATE ANY EXISTING DERMATITIS (SKIN CONDITION). ======================= First Aid Measures ======================= First Aid:EYES:FLUSH W/PLENTY OF WATER FOR FOR AT LEAST 15 MIN. GET MD IF IRRIT PERSISTS. SKIN:WASH W/PLENTY OF SOAP & WATER FOR SEVERAL MIN. GET MD IF IRRIT DEVELOPS/PERSISTS. INGEST:IF MORE THAN SEVERAL MOUTH FULS HAVE BEEN SWALLOWED, GIVE TWO GLASSES OF WATER (16 OZ.) GET MD. INHAL:IF IRRIT, HDCH, NAUS/DROWS OCCURS, REMOVE TO FRESH AIR. GET MD IF BRTHG BECOMES DFCLT/SYMP PERSIST. ===================== Fire Fighting Measures ===================== Flash Point Method:COC Flash Point:345F,174C Extinguishing Media:ACCORDING TO NFPA GUIDE, USE WATER SPRAY, DRY CHEMICAL, FOAM, OR CO2. Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . WATER/FOAM MAY CAUSE FROTHING. USE WATER TO COOL FIRE-EXPSD CNTNRS. IF LEAK/SPILL HAS IGNITED, (SUPP DATA) Unusual Fire/Explosion Hazard:NONE ================== Accidental Release Measures ================== Spill Release Procedures:VENT AREA. AVOID BRTHG VAP. USE NIOSH/MSHA APPRVD SCBA OR SUPPLIED AIR FOR LRG SPILLS/CONFINED AREA. CONTAIN SPILL IF POSSIBLE. WIPE UP/ABSORB ON SUITABLE MATL & SHOVEL UP. PREVENT ENTRY INTO SEWERS & WATERWAYS. AVOID CONT W/SKIN, EYES/CLTHG. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:MINIMUM FEASIBLE HANDLING TEMPS SHOULD BE MAINTAINED. PERIODS OF EXPOS TO HIGH TEMPS SHOULD BE MINIMIZED. WATER CONTAM SHOULD BE AVOIDED. Other Precautions:REMOVE & DRY CLEAN OR LAUNDER CLTHG SOAKED OR SOILED W/ THIS MATL BEFORE REUSE. DRY CLEANING OF CONTAM CLTHG MAY BE MORE EFFECTIVE THAN NORMAL LAUNDERING. INFORM INDIV RESPONSIBLE FOR CLEANING OF POTE NTIAL HAZ ASSOC W/HNDLG CONTAM CLTHG. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:AIRBORNE CONC SHOULD BE KEPT TO LOWEST LEVELS POSS. IF VAPOR, MIST OR DUST, IS GENERATED, USE NIOSH/MSHA APPROVED RESPIRATOR AS APPROPRIATE. NIOSH/MSHA APPRVD SUPPLIED AIR RESP PROT SHOULD BE USED FOR CLEANING LRG SPILLS/UPON (SEE ING 4) Ventilation:ADEQUATE TO MEET COMPONENT OCCUPATIONAL EXPOSURE LIMITS. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:CHEM WORK GOGG/FULL LENGTH FACESHLD Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. Work Hygienic Practices:WASH EXPOSED SKIN SEV TIMES DAILY W/SOAP & WATER. SOILED WORK CLTHG SHOULD BE LAUNDERED/DRY CLEANED AT LEAST ONCE A WEEK Supplemental Safety and Health FIRE FIGHT PROC: USE WATER SPRAY TO DISPERSE VAPS & TO PROVIDE PROT FOR PERSONS ATTEMPTING TO STOP LEAK. EFTS OF OVEREXP: NAUS & DIARR MAY OCCUR. (CHRONIC) NO ADVERSE EFFECTS ANTICIPATED. WASTE DISP M ETH: WASTE. THIS IS BECAUSE PROD USES, TRANSFORMATIONS, MIXT, PROCESSES, ETC, MAY RENDER RESULTING MATLS (SEE ING 5) ================== Physical/Chemical Properties ================== HCC:V6 Spec Gravity:0.8855 Appearance and Odor:CLEAR PURPLE LIQUID. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZERS. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:TOXIC LEVELS OF CO, CO2, IRRIT ALDEHYDES & KETONES, & COMBUST PRODS OR COMPOUNDS OF NITROGEN. ==================== Disposal Considerations ==================== Waste Disposal Methods:THIS PROD HAS BEEN EVAL FOR RCRA CHARACT & DOES NOT MEET CRITERIA OF HAZ WASTE IF DISCARDED IN ITS PURCHASED FORM. UNDER RCRA, IT IS RESPONSIBILITY OF USER OF PROD TO DETERMINE AT TIME OF DISP, WHETHE R THE PROD MEETS RCRA CRITERIA FOR HAZ (SUPP DATA) Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.