MARSULEX INC -- SULFURIC ACID, 98% -- 6810-00N050198
=====================  Product Identification  =====================

Product ID:SULFURIC ACID, 98%
MSDS Date:02/01/1990
FSC:6810
NIIN:00N050198
=== Responsible Party ===
Company Name:MARSULEX INC
Address:40 RICHARDS AVE
Box:5453
City:NORWALK
State:CT
ZIP:06856-5453
Country:US
Info Phone Num:203-854-0300
Emergency Phone Num:800-263-9502
CAGE:MARSU
=== Contractor Identification ===
Company Name:MARSULEX INC
Address:40 RICHARDS AVE
Box:5453
City:NORWALK
State:CT
ZIP:06856-5453
Country:US
Phone:203-854-0300
CAGE:MARSU

=============  Composition/Information on Ingredients  =============

Ingred Name:NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE APPROPRIATE MEDIA TO EXTINGUISH SOURCE OF FIRE.
    USE WATER CAREFULLY.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
    FIRE INVOLVING SM AMT OF COMBUSTS MAY BE SMOTHERED W/SUITABLE DRY
    CHEM. USE WATER ON COMBUSTS (SUPP DATA)
Unusual Fire/Explosion Hazard:NOT FLAMM BUT HIGHLY REACTIVE; CAPABLE OF
    IGNITING FINELY DIVIDED COMBUST MATLS ON CONT. REACTS VIOLENTLY
    W/WATER & ORG MATLS W/EVOLUTION OF HEAT. (SUPP DATA)

=============  Exposure Controls/Personal Protection  =============

Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:626F,330C
Melt/Freeze Pt:M.P/F.P Text:30.0F,-1.1C
Vapor Pres:0.002 @40C
Spec Gravity:1.8437
pH:SUPDAT
Solubility in Water:MISCIBLE
Appearance and Odor:CLEAR TO AMBER, HEAVY, OILY LIQUID W/SHARP
    PENETRATING SO*2 ODOR.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
CONT W/ORG MATLS (SUCH AS CHLORATES, CARBIDES, FULMINATES & PICRATES)
    MAY CAUSE FIRE & EXPLOS. CONT W/METALS MAY (ING 3)
Stability Condition to Avoid:TEMPERATURES WHICH MAY HAVE NEGATIVE
    EFFECT ON MATERIALS OF CONSTRUCTION USED IN EQUIPMENT.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their