AIRGAS -- AMMONIA -- 6830-00-616-9184
=====================  Product Identification  =====================

Product ID:AMMONIA
MSDS Date:05/01/1990
FSC:6830
NIIN:00-616-9184
=== Responsible Party ===
Company Name:AIRGAS
Address:100 MAISONFORD RD, 5 RADNOR CORP CENTER
City:RADNOR
State:PA
ZIP:19067
Country:US
Info Phone Num:215-687-5253
Emergency Phone Num:215-687-5253
CAGE:AIRGA
=== Contractor Identification ===
Company Name:AIRGAS
Address:100 MATSONFORD ROAD, 5 RADNOR CORP CNTR
City:RADNOR
State:PA
ZIP:19087
Country:US
Phone:215-687-5253
CAGE:AIRGA
Company Name:AIRGAS INC
Address:100 MATSONFORD RD SUITE 550
Box:City:WAYNE
State:PA
ZIP:19087
Country:US
Phone:215-687-5253
CAGE:0MN39

=============  Composition/Information on Ingredients  =============

Ingred Name:AMMONIA (SARA 302/313) (CERCLA)
CAS:7664-41-7
RTECS #:BO0875000
Fraction by Wt: 100%
OSHA PEL:50 PPM
ACGIH TLV:25 PPM;35 STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:SUPP DATA:CHROMYL CHLORIDE, TRIOXYGEN DIFLUORIDE, NITROGEN
    DIOXIDE & NITROGEN TRICHLORIDE.
RTECS #:9999999ZZ

Ingred Name:EFTS OF OVEREXP:TISS CAUSES CAUSTIC LIKE BURNS & SKIN
    LESIONS RESULTING IN EARLY NECROSIS & SCARRING. BURNS TO (ING 4)
RTECS #:9999999ZZ

Ingred Name:ING 3:EYE RSLT IN LESIONS & POSS LOSS OF VISION. CRYOGENIC
    "BURNS" ARE LIKE FROSTBITE W/CHANGE IN SKIN COLOR TO (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4:GRAY/WHITE POSS FOLLOWED BY BLISTERING.
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC:THAT MUC/VOMITED MATL DOES NOT OBSTRUCT
    AIRWAY BY POSITIONAL DRAINAGE. FURTHER TREATMENT SHOULD BE(ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:SYMPTOMATIC & SUPPORTIVE. EYE:FLUSH CONTAM EYE(S)
    W/COPIOUS QTYS OF WATER. PART EYELIDS TO ASSURE COMPLETE (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:FLUSHING. CONTINUE FOR A MIN OF 15 MINS. SKIN:FLUSH
    AFFECTED AREA W/COPIOUS QTYS OF WATER. REMOVE AFFECTED (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:CLTHG AS RAPIDLY AS POSS. DERMAL
    CONT/FROSTBITE:REMOVE CONTAM CLTHG & FLUSH AFFECTED AREAS
    W/LUKEWARM (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:WATER. DO NOT USE HOT WATER. MD SHOULD SEE PATIENT
    PROMPTLY IF CRYOGENIC "BURN" HAS RESULTED IN BLISTERING(ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:OF DERMAL SURFACE OR DEEP TISSUE FREEZING.
RTECS #:9999999ZZ

Ingred Name:OTHER PREC:CONNECTING CYL TO LOWER PRESS (<500 PSIA)
    PIPING/SYS. DO NOT HEAT CYL BY ANY MEANS TO INCR DISCHARGE (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:RATE OF PROD FROM CYL. USE CHECK VALVE/TRAP IN
    DISCHARGE LINE TO PVNT HAZ BACK FLOW INTO CYL. DO NOT (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:ALLOW TEMP WHERE CYLS ARE STORED TO EXCEED
    130F(54C). CYLS SHOULD BE STORED UPRIGHT & FIRMLY SECURED TO (ING
    15)
RTECS #:9999999ZZ

Ingred Name:ING 14:PVNT FALLING/BEING KNOCKED OVER. FULL & EMPTY CYLS
    SHOULD BE SEGREGATED. USE "FIRST IN - FIRST OUT" (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:INVENTORY SYS TO PVNT FULL CYLS BEING STORED FOR
    EXCESSIVE PERIODS OF TIME. POST "NO SMOKING/OPEN FLAMES"(ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:SIGNS IN STOR/USE AREA. THERE SHOULD BE NO SOURCES
    OF IGNIT IN STOR/USE AREA. FOR ADDNL HNDLG/STOR RECS, (ING 18)
RTECS #:9999999ZZ

Ingred Name:ING 17:CONSULT COMPRESSED GAS ASSOC'S PAMPHLETS P-1 & G-2.
    GASEOUS/LIQ ANHYDROUS AMMONIA CORRODES CERTAIN METALS(ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 18:AT AMBIENT TEMPS. OXYG PRESENCE ENHANCES CORR OF
    ORDINARY/SEMI-ALLOY STEELS. ADDN OF WATER INHIBITS THIS (ING 20)
RTECS #:9999999ZZ

Ingred Name:ING 19:ENHANCEMENT. KEEP ANHYDROUS AMMONIA SYS SCRUPULOUSLY
    DRY. EARTH-GROUND & BOND ALL LINES & EQUIP ASSOC W/ (ING 21)
RTECS #:9999999ZZ

Ingred Name:ING 20:AMMONIA SYS. ELEC EQUIP SHOULD BE NON-SPARKING/EXPLO
    PROOF. COMPRESSED GAS CYLS SHOULD NOT BE REFILLED (ING 22)
RTECS #:9999999ZZ

Ingred Name:ING 21:EXCEPT BY QUALIFED PRDCRS OF COMPRESSED GASES.
    SHIPMENT OF COMPRESSED GAS CYL WHICH HAS NOT BEEN FILLED (ING 23)
RTECS #:9999999ZZ

Ingred Name:ING 22:BY OWNER/WITH HIS (WRITTEN) CONSENT IS VIOLATION OF
    FED LAW (49CFR). ALWAYS SECURE CYLS IN UPRIGHT (ING 24)
RTECS #:9999999ZZ

Ingred Name:ING 23:POSITION BEFORE TRANSPORTING THEM. NEVER TRANSPORT
    CYLS IN TRUNKS OF VEHICLES, ENCLSD VANS, TRUCK CABS/IN(ING 25)
RTECS #:9999999ZZ

Ingred Name:ING 24:PASSENGER COMPARTMENTS. TRANSPORT CYLS SECURED IN
    OPEN FLATBED/IN OPEN PICK-UP TYPE VEHICLES.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:CORR & IRRIT TO SKIN, EYES, UPPER RESP
    SYS & ALL MUCOSAL TISS. DEPENDING ON CONC INHALED, IT MAY CAUSE
    BURNING SENSATIONS, COUGH, WHEEZING, SHORTNESS OF BREATHE, HDCH,
    NAUS, W/EVENTUAL COLLAPSE. MILD  CONCS OF VAP WILL CAUSE DERM/CONJ.
    HIGHER CONCS OF VAP/LIQ CONT WILL CAUSE CAUSTIC-LIKE DERMAL BURNS &
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INFLAMM & SWELL OF EYES W/POSS LOSS OF
    VISION. RAPIDLY EVAP LIQ CONTACTING DERMAL TISS/EYES CAN CAUSE
    CRYOGENIC "BURNS". INHAL:AFFECTS UPPER AIRWAY (LARYNX & BRONCHI) BY
    CAUSING CAUSTIC-LIKE  BURNING RESULTING IN EDEMA & CHEM PNEUM. IF
    IT ENTERS DEEP LUNG, PULM EDEMA WILL RSLT. TOX LEVEL EXPOS TO
    DERMAL (ING 3)
Medical Cond Aggravated by Exposure:PERSONS IN ILL HEALTH WHERE SUCH
    ILLNESS WOULD BE AGGRAVATED BY EXPOSURE TO AMMONIA SHOULD NOT BE
    ALLOWED TO WORK WITH OR HANDLE THIS PRODUCT.

=======================  First Aid Measures  =======================

First Aid:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP TO
    AMMONIA. RESCUE PERS SHOULD BE EQUIPPED W/NIOSH/MSHA APPRVD SCBA &
    BE COGNIZANT OF FIRE & EXPLO HAZ. INGEST:CALL MD IMMED .
    INHAL:CONSCIOU S PERS SHOULD BE ASSISTED TO UNCONTAM AREA & INHALE
    FRESH AIR. UNCON PERS SHOULD BE MOVED TO UNCONTAM AREA & GIVEN
    MOUTH-TO-MOUTH RESUSCITATION & SUPP OXYG. KEEP VICTIM WARM & QUIET.
    ASSURE (ING 6)

=====================  Fire Fighting Measures  =====================

Flash Point:GAS
Lower Limits:15%
Upper Limits:27%
Extinguishing Media:WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
    IF POSS, STOP FLOW OF GAS. SINCE AMMONIA IS SOL IN WATER, IT IS
    BEST EXTING MEDIA - NOT ONLY EXTING(SUPDAT)
Unusual Fire/Explosion Hazard:MIN IGNIT ENERGY FOR AMMONIA IS VERY
    HIGH. IT IS APPROX 500 TIMES GREATER THAN ENERGY REQD FOR IGNITING
    HYDROCARBONS & 1000-10,000 TIMES GREATER THAN (SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE
    APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE
    PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN
    CNTNR/CNTNR VALVE, CONT YOUR  CLOSEST SUPPLIER LOCATION/CALL
    EMERGENCY (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:PROT CYLS FROM PHYSICAL DMG. STORE IN
    COOL, DRY, WELL-VENTED AREA OF NONCOMBUST CONSTRUCTION AWAY FROM
    HEAVILY TRAFFICKED AREAS & EMERGENCY EXITS.
Other Precautions:USE ONLY IN WELL-VENTED AREAS. VALVE PROT CAPS MUST
    REMAIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE OUTLET PIPED TO USE
    POINT. DO NOT DRAG, SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK FOR
    CYL MOVEMENT. U SE PRESS REDUCING REGULATOR WHEN(ING 12)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
    W/MASK OR SELF-CONTAINED BREATHING APPARATUS SHOULD BE AVAILABLE
    FOR EMERGENCY USE.
Ventilation:HOOD W/FORCED VENT. LOCAL EXHAUST:TO PREVENT ACCUMULATION
    ABOVE TWA. MECHANICAL (GENERAL):I/A/W ELECTRICAL CODES.
Protective Gloves:PLASTIC OR RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . SAFETY SHOES.
Work Hygienic Practices:PERSONS W/POTENTIAL EXPOSURE TO AMMONIA SHOULD
    NOT WEAR CONTACT LENSES.
Supplemental Safety and Health
FIRE FIGHT PROC:FIRE, BUT ALSO ABSORBING ESCAPED AMMONIA GAS. USE WATER
    SPRAY TO COOL SURROUND CNTNRS. EXPLO HAZ:THAT REQD FOR HYDROGEN.
    SPILL PROC:TELEPHONE NUMBER LISTED. WASTE DISP METH:TELEPHONE N
    UMBER LISTED. EYE PROT:& FULL LGTH FCSHLD . MATLS TO
    AVOID:CHLORIDE, HYDROGEN BROMIDE, NITROSYL CHLORIDE, (ING 2)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-28F,-33C
Melt/Freeze Pt:M.P/F.P Text:-108F,-78C
Vapor Pres:129 PSIA
Spec Gravity:0.59 (AIR=1)
Solubility in Water:VERY SOLUBLE
Appearance and Odor:COLORLESS GAS W/PUNGENT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AMMONIA IS FLAMM OVER RELATIVELY NARROW RANGE IN AIR. IT REACTS
    VIGOROUSLY W/FLUORINE, CHLORINE, HYDROGEN (SUPP DATA)
Hazardous Decomposition Products:HYDROGEN AT VERY HIGH TEMPERATURES
    (1544F,840C).

====================  Disposal Considerations  ====================

Waste Disposal Methods:DO NOT ATTEMPT TO DISP OF WASTE/UNUSED QTYS.
    RETURN IN SHIPPING CNTNR PROPERLY LABELED, W/ANY VALVE OUTLET
    PLUGS/CAPS SECURED & PROT CAP IN PLACE TO YOUR SUPPLIER. FOR EMER
    DISP ASSISTANCE, CONT YOUR	CLOSEST SUPPLIER LOCATION/CALL
    EMERGENCY (SUPDAT)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.