AIRGAS -- AMMONIA -- 6830-00-616-9184
===================== Product Identification ===================== Product ID:AMMONIA MSDS Date:05/01/1990 FSC:6830 NIIN:00-616-9184 === Responsible Party === Company Name:AIRGAS Address:100 MAISONFORD RD, 5 RADNOR CORP CENTER City:RADNOR State:PA ZIP:19067 Country:US Info Phone Num:215-687-5253 Emergency Phone Num:215-687-5253 CAGE:AIRGA === Contractor Identification === Company Name:AIRGAS Address:100 MATSONFORD ROAD, 5 RADNOR CORP CNTR City:RADNOR State:PA ZIP:19087 Country:US Phone:215-687-5253 CAGE:AIRGA Company Name:AIRGAS INC Address:100 MATSONFORD RD SUITE 550 Box:City:WAYNE State:PA ZIP:19087 Country:US Phone:215-687-5253 CAGE:0MN39 ============= Composition/Information on Ingredients ============= Ingred Name:AMMONIA (SARA 302/313) (CERCLA) CAS:7664-41-7 RTECS #:BO0875000 Fraction by Wt: 100% OSHA PEL:50 PPM ACGIH TLV:25 PPM;35 STEL EPA Rpt Qty:100 LBS DOT Rpt Qty:100 LBS Ingred Name:SUPP DATA:CHROMYL CHLORIDE, TRIOXYGEN DIFLUORIDE, NITROGEN DIOXIDE & NITROGEN TRICHLORIDE. RTECS #:9999999ZZ Ingred Name:EFTS OF OVEREXP:TISS CAUSES CAUSTIC LIKE BURNS & SKIN LESIONS RESULTING IN EARLY NECROSIS & SCARRING. BURNS TO (ING 4) RTECS #:9999999ZZ Ingred Name:ING 3:EYE RSLT IN LESIONS & POSS LOSS OF VISION. CRYOGENIC "BURNS" ARE LIKE FROSTBITE W/CHANGE IN SKIN COLOR TO (ING 5) RTECS #:9999999ZZ Ingred Name:ING 4:GRAY/WHITE POSS FOLLOWED BY BLISTERING. RTECS #:9999999ZZ Ingred Name:FIRST AID PROC:THAT MUC/VOMITED MATL DOES NOT OBSTRUCT AIRWAY BY POSITIONAL DRAINAGE. FURTHER TREATMENT SHOULD BE(ING 7) RTECS #:9999999ZZ Ingred Name:ING 6:SYMPTOMATIC & SUPPORTIVE. EYE:FLUSH CONTAM EYE(S) W/COPIOUS QTYS OF WATER. PART EYELIDS TO ASSURE COMPLETE (ING 8) RTECS #:9999999ZZ Ingred Name:ING 7:FLUSHING. CONTINUE FOR A MIN OF 15 MINS. SKIN:FLUSH AFFECTED AREA W/COPIOUS QTYS OF WATER. REMOVE AFFECTED (ING 9) RTECS #:9999999ZZ Ingred Name:ING 8:CLTHG AS RAPIDLY AS POSS. DERMAL CONT/FROSTBITE:REMOVE CONTAM CLTHG & FLUSH AFFECTED AREAS W/LUKEWARM (ING 10) RTECS #:9999999ZZ Ingred Name:ING 9:WATER. DO NOT USE HOT WATER. MD SHOULD SEE PATIENT PROMPTLY IF CRYOGENIC "BURN" HAS RESULTED IN BLISTERING(ING 11) RTECS #:9999999ZZ Ingred Name:ING 10:OF DERMAL SURFACE OR DEEP TISSUE FREEZING. RTECS #:9999999ZZ Ingred Name:OTHER PREC:CONNECTING CYL TO LOWER PRESS (<500 PSIA) PIPING/SYS. DO NOT HEAT CYL BY ANY MEANS TO INCR DISCHARGE (ING 13) RTECS #:9999999ZZ Ingred Name:ING 12:RATE OF PROD FROM CYL. USE CHECK VALVE/TRAP IN DISCHARGE LINE TO PVNT HAZ BACK FLOW INTO CYL. DO NOT (ING 14) RTECS #:9999999ZZ Ingred Name:ING 13:ALLOW TEMP WHERE CYLS ARE STORED TO EXCEED 130F(54C). CYLS SHOULD BE STORED UPRIGHT & FIRMLY SECURED TO (ING 15) RTECS #:9999999ZZ Ingred Name:ING 14:PVNT FALLING/BEING KNOCKED OVER. FULL & EMPTY CYLS SHOULD BE SEGREGATED. USE "FIRST IN - FIRST OUT" (ING 16) RTECS #:9999999ZZ Ingred Name:ING 15:INVENTORY SYS TO PVNT FULL CYLS BEING STORED FOR EXCESSIVE PERIODS OF TIME. POST "NO SMOKING/OPEN FLAMES"(ING 17) RTECS #:9999999ZZ Ingred Name:ING 16:SIGNS IN STOR/USE AREA. THERE SHOULD BE NO SOURCES OF IGNIT IN STOR/USE AREA. FOR ADDNL HNDLG/STOR RECS, (ING 18) RTECS #:9999999ZZ Ingred Name:ING 17:CONSULT COMPRESSED GAS ASSOC'S PAMPHLETS P-1 & G-2. GASEOUS/LIQ ANHYDROUS AMMONIA CORRODES CERTAIN METALS(ING 17) RTECS #:9999999ZZ Ingred Name:ING 18:AT AMBIENT TEMPS. OXYG PRESENCE ENHANCES CORR OF ORDINARY/SEMI-ALLOY STEELS. ADDN OF WATER INHIBITS THIS (ING 20) RTECS #:9999999ZZ Ingred Name:ING 19:ENHANCEMENT. KEEP ANHYDROUS AMMONIA SYS SCRUPULOUSLY DRY. EARTH-GROUND & BOND ALL LINES & EQUIP ASSOC W/ (ING 21) RTECS #:9999999ZZ Ingred Name:ING 20:AMMONIA SYS. ELEC EQUIP SHOULD BE NON-SPARKING/EXPLO PROOF. COMPRESSED GAS CYLS SHOULD NOT BE REFILLED (ING 22) RTECS #:9999999ZZ Ingred Name:ING 21:EXCEPT BY QUALIFED PRDCRS OF COMPRESSED GASES. SHIPMENT OF COMPRESSED GAS CYL WHICH HAS NOT BEEN FILLED (ING 23) RTECS #:9999999ZZ Ingred Name:ING 22:BY OWNER/WITH HIS (WRITTEN) CONSENT IS VIOLATION OF FED LAW (49CFR). ALWAYS SECURE CYLS IN UPRIGHT (ING 24) RTECS #:9999999ZZ Ingred Name:ING 23:POSITION BEFORE TRANSPORTING THEM. NEVER TRANSPORT CYLS IN TRUNKS OF VEHICLES, ENCLSD VANS, TRUCK CABS/IN(ING 25) RTECS #:9999999ZZ Ingred Name:ING 24:PASSENGER COMPARTMENTS. TRANSPORT CYLS SECURED IN OPEN FLATBED/IN OPEN PICK-UP TYPE VEHICLES. RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:CORR & IRRIT TO SKIN, EYES, UPPER RESP SYS & ALL MUCOSAL TISS. DEPENDING ON CONC INHALED, IT MAY CAUSE BURNING SENSATIONS, COUGH, WHEEZING, SHORTNESS OF BREATHE, HDCH, NAUS, W/EVENTUAL COLLAPSE. MILD CONCS OF VAP WILL CAUSE DERM/CONJ. HIGHER CONCS OF VAP/LIQ CONT WILL CAUSE CAUSTIC-LIKE DERMAL BURNS & (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:INFLAMM & SWELL OF EYES W/POSS LOSS OF VISION. RAPIDLY EVAP LIQ CONTACTING DERMAL TISS/EYES CAN CAUSE CRYOGENIC "BURNS". INHAL:AFFECTS UPPER AIRWAY (LARYNX & BRONCHI) BY CAUSING CAUSTIC-LIKE BURNING RESULTING IN EDEMA & CHEM PNEUM. IF IT ENTERS DEEP LUNG, PULM EDEMA WILL RSLT. TOX LEVEL EXPOS TO DERMAL (ING 3) Medical Cond Aggravated by Exposure:PERSONS IN ILL HEALTH WHERE SUCH ILLNESS WOULD BE AGGRAVATED BY EXPOSURE TO AMMONIA SHOULD NOT BE ALLOWED TO WORK WITH OR HANDLE THIS PRODUCT. ======================= First Aid Measures ======================= First Aid:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP TO AMMONIA. RESCUE PERS SHOULD BE EQUIPPED W/NIOSH/MSHA APPRVD SCBA & BE COGNIZANT OF FIRE & EXPLO HAZ. INGEST:CALL MD IMMED . INHAL:CONSCIOU S PERS SHOULD BE ASSISTED TO UNCONTAM AREA & INHALE FRESH AIR. UNCON PERS SHOULD BE MOVED TO UNCONTAM AREA & GIVEN MOUTH-TO-MOUTH RESUSCITATION & SUPP OXYG. KEEP VICTIM WARM & QUIET. ASSURE (ING 6) ===================== Fire Fighting Measures ===================== Flash Point:GAS Lower Limits:15% Upper Limits:27% Extinguishing Media:WATER. Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . IF POSS, STOP FLOW OF GAS. SINCE AMMONIA IS SOL IN WATER, IT IS BEST EXTING MEDIA - NOT ONLY EXTING(SUPDAT) Unusual Fire/Explosion Hazard:MIN IGNIT ENERGY FOR AMMONIA IS VERY HIGH. IT IS APPROX 500 TIMES GREATER THAN ENERGY REQD FOR IGNITING HYDROCARBONS & 1000-10,000 TIMES GREATER THAN (SUPDAT) ================== Accidental Release Measures ================== Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CNTNR/CNTNR VALVE, CONT YOUR CLOSEST SUPPLIER LOCATION/CALL EMERGENCY (SUPDAT) Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:PROT CYLS FROM PHYSICAL DMG. STORE IN COOL, DRY, WELL-VENTED AREA OF NONCOMBUST CONSTRUCTION AWAY FROM HEAVILY TRAFFICKED AREAS & EMERGENCY EXITS. Other Precautions:USE ONLY IN WELL-VENTED AREAS. VALVE PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE OUTLET PIPED TO USE POINT. DO NOT DRAG, SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK FOR CYL MOVEMENT. U SE PRESS REDUCING REGULATOR WHEN(ING 12) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE W/MASK OR SELF-CONTAINED BREATHING APPARATUS SHOULD BE AVAILABLE FOR EMERGENCY USE. Ventilation:HOOD W/FORCED VENT. LOCAL EXHAUST:TO PREVENT ACCUMULATION ABOVE TWA. MECHANICAL (GENERAL):I/A/W ELECTRICAL CODES. Protective Gloves:PLASTIC OR RUBBER GLOVES. Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT) Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA . SAFETY SHOES. Work Hygienic Practices:PERSONS W/POTENTIAL EXPOSURE TO AMMONIA SHOULD NOT WEAR CONTACT LENSES. Supplemental Safety and Health FIRE FIGHT PROC:FIRE, BUT ALSO ABSORBING ESCAPED AMMONIA GAS. USE WATER SPRAY TO COOL SURROUND CNTNRS. EXPLO HAZ:THAT REQD FOR HYDROGEN. SPILL PROC:TELEPHONE NUMBER LISTED. WASTE DISP METH:TELEPHONE N UMBER LISTED. EYE PROT:& FULL LGTH FCSHLD . MATLS TO AVOID:CHLORIDE, HYDROGEN BROMIDE, NITROSYL CHLORIDE, (ING 2) ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:-28F,-33C Melt/Freeze Pt:M.P/F.P Text:-108F,-78C Vapor Pres:129 PSIA Spec Gravity:0.59 (AIR=1) Solubility in Water:VERY SOLUBLE Appearance and Odor:COLORLESS GAS W/PUNGENT ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES AMMONIA IS FLAMM OVER RELATIVELY NARROW RANGE IN AIR. IT REACTS VIGOROUSLY W/FLUORINE, CHLORINE, HYDROGEN (SUPP DATA) Hazardous Decomposition Products:HYDROGEN AT VERY HIGH TEMPERATURES (1544F,840C). ==================== Disposal Considerations ==================== Waste Disposal Methods:DO NOT ATTEMPT TO DISP OF WASTE/UNUSED QTYS. RETURN IN SHIPPING CNTNR PROPERLY LABELED, W/ANY VALVE OUTLET PLUGS/CAPS SECURED & PROT CAP IN PLACE TO YOUR SUPPLIER. FOR EMER DISP ASSISTANCE, CONT YOUR CLOSEST SUPPLIER LOCATION/CALL EMERGENCY (SUPDAT) Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.